What is FRL in compressor?
What is FRL in compressor?
An FRL combines a filter, regulator, and lubricator into one component to keep air compressor systems in optimal working condition. FRL Components. An FRL has three primary components: Airline filter. Pressure regulator.
What does a filter regulator lubricator do?
Filter, regulator, and lubricator (FRL) compressed air systems are used to deliver clean air, at a fixed pressure, and lubricated (if needed) to ensure proper pneumatic component operation and increase their operation lifetime.
What is the regulator of FRL?
An FRL consists of three elements – a filter (F) to, generally, remove particles above 40 micron in size and water, a regulator (R), which controls pressure and a lubricator (L), to provide a controlled quantity of oil into the system.
What is the function of filter in FRL unit?
Function of FRL unit Filter (F) – 1) To remove the micron and sub-micron particles present in the entering air of compressor.
Which oil is used in FRL?
FRL Lubricating Oil, Grade: 20W50
Grade | 20W50 |
---|---|
Density | 0.66 g/cm3 |
Physical State | Liquid |
Packaging Size | 1 Liter |
Flash Point | 40 Deg C |
How do I fill my FRL oil?
Filling the lubricant First, remove the oil bowl and fill oil below the maximum level. With pulling the stopper down, turn the oil bowl to either side to remove it. Re-assemble the oil bowl to the unit and re-connect the air supply. Pour oil in the same way or through the unscrewed lubricant hole from the next time.
Which oil is used in FRL unit?
SAE petroleum based detergent automotive motor oil may be used. If you can not find a straight 10wt. SAE then we suggest using straight 20wt. SAE petroleum based detergent automotive motor oil.
What does an FRL of 60 60 30 mean?
Figure 1 below shows an FRL of 60/60/60. This means that if a building element were exposed to a standard fire test, it would not be expected to fail for 60 minutes in each of the three criteria. The BCA specifies FRLs for building elements such as walls, columns, roofs and floors.
How do you calculate FRL?
The class and type of construction and the type of building element is used to determine what FRL is required. As an example, a wall between apartments in a 4-storey apartment building will require an FRL of 90/90/90 if it is loadbearing or -/60/60 if it is not.
How do I add oil to my FRL?
To add oil, remove the black oil plug at the top of the oiler with a ¼” hex wrench, add oil and replace the plug. USE NON- FLUID OIL. Oil can be added with either the air supply on or off. The air pressure is indicated on the dial gauge on the front of the Pressure Regulator.