What is the clearance above an electrical panel?

110-26 of the National Electrical Code (NEC): 1) at least a 3-ft clearance in front of all electrical equipment; 2) a 30 in. -wide working space in front of equipment operating at 600V or less; and 3) minimum headroom clearance of 6 ft or the height of the equipment, whichever is greater.

What is the OSHA standard for electrical panel clearance?

three feet
29 CFR 1910.303(g). For equipment operating at 600 volts, nominal or less to ground, electrical panels must have a minimum of three feet of clearance in front of the panel and a minimum clearance width of 2.5 feet or the width of the equipment, whichever is greater.

How much clearance is required around an electrical panel?

A: According to NFPA 70-2011, article 110.26, a minimum of 36 inches clearance is required in front of all electrical equipment, including controls and panels, extending from the floor to a height of 6 foot 6 inches or the height of the equipment whichever is higher.

What is the code for electrical panel?

NEC code states that panels must have clearance of 36 inches in front, 30 inches to the sides, and a working area with a clearance of 6 foot 5 inches. You’ll likely need a permit to move an electric panel. A garage or basement is ideal because it meets all these requirements.

Why do electrical panels need 36 inches of clearance?

Obstructed access to electrical panels and switches can prevent personnel from shutting down the source of power in the event of an accident. OSHA regulations and the National Electrical Code requires a clearance of at least 36 inches (3 feet)in front of electrical panels and electrical switches.

How much space do you need around a breaker box?

According to the NEC, the working space around the breaker panel must be at least 6′ 6” high and 3 feet square away from the wall, with 30” width. This allows the door to be opened to the panel, with nothing blocking the area.

What is code for an electrical panel?

How high does an electrical box have to be from the floor?

about 16-inches
As for typical heights, that isn’t as well-regulated (and we’re glad for that). Generally, you want to mount receptacle boxes with the bottom of the box about 16-inches off the floor. Coincidentally, this roughly equates to the same height as your garden variety 22-ounce framing hammer.

Can a breaker panel be in a corner?

This means you cannot place an electrical panel close to a corner if another wall, fixture or piece of furniture is within 30 inches of it.